![Nortel 1002rp Maintenance And Diagnostics Download Page 172](http://html1.mh-extra.com/html/nortel/1002rp/1002rp_maintenance-and-diagnostics_1707105172.webp)
RAID operations
Standard 1.11
172
CallPilot
Result:
The RAID configuration utility opens.
3
Break the mirroring of the logical drives.
a.
Select Objects
➝
Physical Drive.
Note:
All server drives on channel 1 must be online.
b.
Select CH1 ID0 (A01-01) and press Enter.
c.
Select Fail Drive and press Enter.
d.
Select Yes to confirm the fail action and press Enter.
e.
Repeat these steps for each remaining drive on channel 2:
CH1 ID1 (A02-01) and CH1 ID2 (A03-01).
4
Bring the drives on channel 2 online (the drives on which the
previous CallPilot release is installed).
a.
Select Objects
➝
Physical Drive.
b.
Select CH2 ID0 (A01-02) and press Enter.
c.
Select Make Online and press Enter.
d.
Select Yes to confirm that the driver must be brought online and
press Enter.
e.
Repeat these steps for each remaining drive on channel 2:
CH2 ID1 (A02-02) and CH2 ID2 (A03-02).
5
Press Esc to return to the Objects menu.
6
Press Esc to return to the Management menu.
7
Press Esc to exit the RAID configuration utility.
Result:
A confirmation box appears.
8
Click Yes to confirm that you want to exit the RAID configuration
utility and press Enter.
9
Press Ctrl+Alt+Delete to reboot the server.
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......