Upgrading to High Capacity
Standard 1.11
182
CallPilot
Upgrading to High Capacity: M1/CS1000 switch connectivity
To add two MPB96 boards
1
Courtesy stop all CallPilot channels.
2
Power down the server and all peripheral devices.
3
Disconnect the following cables:
a.
power cable
b.
peripheral device cable
c.
DS30X cables
4
Remove the server cover.
For instructions on removing the server cover, see “Removing the
front bezel and server cover” on page 110.
5
Disconnect the CT Bus cable (if present).
6
Ensure that there is an existing MPB96 board in PCI slot 3 (this is
standard for a 96-channel configuration).
7
Plug the first additional MPB96 board into PCI slot 6.
8
Plug the second additional MPB96 board into PCI slot 9.
9
Connect the 7-drop CT Bus cable to the MPB96 boards; the
connectors of the CT Bus cable must connect to the three MPB96
boards in slots 3, 6, and 9.
Note:
There should be no dangling connectors at either end of the
CT Bus cable.
10
Replace the server cover.
11
Replace the front bezel and lock it.
12
Reconnect the peripheral device and power cables.
13
Reconnect the DS30X cable to the faceplate of the MPB96 board.
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......