RAID operations
1002rp Server Maintenance and Diagnostics
165
Result:
The system should display both SCSI channels, each
having three drives. SCSI ID
'
s should be listed in order from 0 to 2
for each channel, starting from the top. All disk drives should be in
READY state.
Note:
Do not use the Load command on the Configure menu. This
command is not for RAID operations.
11
Create the first logical drive by selecting A01-01 (first drive from
channel 0), to A01-02 (first drive from channel 1) and pressing the
space bar.
Result:
After selection, the drives will blink.
12
Press Enter to create the first logical drive.
13
Repeat the process for the second and third logical drives to create
packs as follows:
A02-01 and A02-02 as second pack
A03-01 and A03-02 as third pack
14
Press Enter or F10 to configure the logical drives.
15
Press the space bar to Select Configuration Array.
Span-1
appears
in the box opened for A01 logical drive. DO NOT select and press
the space bar for the other logical drives at this point.
16
Configure logical drive A01, by pressing F10.
RAID 1
;
Size:
accept the size displayed;
Accep
t
SPAN
= NO
17
Highlight Accept and press Enter to accept these new values.
Repeat for the two remaining logical drives.
Result:
After the last logical drive, the system will prompt you to
save the configuration.
18
Highlight YES and press Enter.
19
Press ESC twice to exit the submenus.
20
In the Management menu choose the Initialize submenu.
21
Press F2 to select all three logical drives.
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......