January 2007
Maintaining the Pentium III SBC card
1002rp Server Maintenance and Diagnostics
207
Result:
The system updates the BIOS and then prompts you to
reboot the server.
11
Press Ctrl+Alt+Delete to reboot the CallPilot server.
Result:
The CallPilot server reboots.
12
During the reboot sequence, check the version of the BIOS on the
top of the first screen. The BIOS version must be NNCXUA07.
Tip:
If the BIOS version is not NNCXUA07, then check if the J10
and J11 jumpers are both in the top position. Power down the
server, remove the single board computer (SBC) board and set the
jumpers to the correct position. Follow the electrostatic discharge
(ESD) rules to prevent static electricity from damaging the SBC
board.
To configure the Pentium III SBC
1
Restart the server, and then press Delete to enter Setup when
prompted.
2
Set the MPS 1.4 Support value to Disabled in the Chipset menu.
3
Press F9 to accept the other default values.
4
Press Enter when prompted to confirm this change.
5
Press F10 to save and exit the BIOS setup.
6
Restart the server.
Result:
BIOS reconfiguration is completed.
.
CAUTION
Risk of data loss
Perform this procedure only if specifically instructed to do so
by your Nortel representative.
Summary of Contents for 1002rp
Page 6: ...Standard 1 11 6 CallPilot...
Page 14: ...Contents Standard 1 11 14 CallPilot...
Page 30: ...Troubleshooting your CallPilot system Standard 1 11 30 CallPilot...
Page 92: ...Using CallPilot Manager to monitor hardware Standard 1 11 92 CallPilot...
Page 108: ...Using CallPilot system utilities Standard 1 11 108 CallPilot...
Page 138: ...Replacing basic chassis components Standard 1 11 138 CallPilot...
Page 156: ...Replacing media drives Standard 1 11 156 CallPilot...
Page 190: ...Replacing voice processing boards Standard 1 11 190 CallPilot...
Page 216: ...Index Standard 1 11 216 CallPilot...
Page 217: ......