Instruction Manual
OCM F
OCM F - Rev. 04 as of 18.02.2014
Page 57
9.4.6 Parameter Menu “Analog Outputs“
Fig. 9-36
Menü Analogausgang
Innerhalb dieses Menüs kann zwischen den Analogausgängen 1-3 mit den Pfeil-
tasten >rechts< oder >links< gewählt werden.
Function
The selected analog output is going to be assigned to a function.
Select from various functions:
-
Not active (no analog signal output)
-
Flow rate (output of analog signal which is proportional to calculated flow
volume)
-
Level (output of analog signal which is proportional to measured filling level)
-
Velocity (output of analog signal which is proportional to mean flow velocity
averaged from measured individual velocities)
-
Temperature (output of measured water temperature as analog signal)
-
Constant current (calculates from the ratio between valid readings to total
readings resulting from velocity measurement, output as analog signal). This
function is not conceived for control purposes, but for monitoring, remote
analysis and for determination of sensor cleaning intervals.
1
Analog output
2
Start measurement
3
Stop measurement (obstruction, standing water or no water etc.)
Fig. 9-37
Analog output signal quality
The Fig. 9-37 signal quality shows the analog output signal if the signal quality
has been programmed. The signal will steeply rise at the beginning of the meas-
urement (2).
The signal is damped in order to avoid heavy signal fluctuation.