Fig. 9-30
Sensor type3: 22 wire probe
ext. Sensor (Ex)
04
Level measurement by external Ex 2-wire sensor supplied by OCM F
e.g. a pressure probe, type NivuBar Plus or echo sounder type Nivu-
Compact). Connect as described in Fig. 7-10.
Fig. 9-31
Sensor type 4: 2-wire probe Ex
Please select the appropriate level measurement method prior to planning the
facility.
The transmitter will access only the clamps which have been programmed in
the menu!
Due to this reason please observe correct sensor connection
(see chapter 7.4.2)
Mounting height
Only visible, if sensor type no. 1 is selected. This value is set to 5 mm
(0.19 in) as KDA combi sensors in standard, which is the position of the dia-
phragm above the channel bottom. There is no need to modify this value
unless the sensor is going to be installed
higher or lower
. If installed higher
(on a block or similar) enter 5 mm (0.19 in) plus additional height, if installed
lower subtract from 5 mm (0.19 in) and enter the total height.