Instruction Manual
OCM F
Page 26
OCM F - Rev. 04 as of 18.02.2014
®
Fig. 7-6
Connection of 1 KDA wedge or pipe sensor (Ex), Type K0 or R0
Fig. 7-7
Connection of 1 KDA combi sensor (Ex) with integrated pres-
sure measurement cell, Type KP
The pressure compensation element serves as connection socket for cable
extension at the same time.
Please observe not to exceed the maximum cable length of 250 m (820 ft)
between KDA sensor and transmitter by taking the maximum permissible re-
sistance into account.
If the level measurement is carried out by a 2-wire probe, (NivuBar, Nivu-
Compact 2-wire echo sounder or similar) which is supplied by the OCM F,
please follow the wiring diagram below:
Fig. 7-8
Connecting an ext. 2-wire sensor (no Ex) for flow level meas-
urement