71
*1: The polarity of input and output ON/OFF can be changed depending on the constant settings.
Item
Model
Remarks
0.1 kW
0.2 kW
0.4 kW
0.75 kW
Stops when motor power line is disconnected.
Pole sensor
Stops when an undefined pattern of the pole sensor is detected.
Undervoltage
Stops when main circuit DC voltage is 215 V or less.
Overspeed
Stops when the rotational speed of motor is 3600 r/min or more
for 1 second.
O
t
h
e
r
s
Connected terminals
Main circuit: Screw terminal,
Control circuit: Plug-in screw terminal
Motor sensor: Connector
A separate relay cable is required to
connect with the motor.
Wiring distance between the
driver and motor
Within 30 m
Overheat protection
Stops when there is abnormal overheating of the driver body.
System error
Error in self-diagnosis of the driver body
S
a
f
e
g
u
a
r
d
s
Instantaneous overcurrent
Stops at approximately 450% or more of rated output current.
Overload
Stops when overload of motor current is detected.
Select detection method according to
the constant settings
▪ Electronic thermal
▪ Motor current continuous
detection
Overvoltage
Stops when main circuit DC voltage is 400 V or more.
Power disconnection