70
O
u
t
p
u
t
*
1
Item
Model
Remarks
0.1 kW
0.2 kW
0.4 kW
0.75 kW
0 to 10 V input
Multi-function output 4
points
Select 4 points from the following 13 points:
1: Error detection signal
2: Brake timing signal
3: Rotation pulse (only C3 and C4 can be selected)
4: CW pulse (only C3 and C4 can be selected)
5: CCW pulse (only C3 and C4 can be selected)
6: Rotation direction signal
7: Signal during operation
8: Signal during rotation
9: Speed matching signal
10: Specified speed over
11: Rated torque over
12: Signal during torque limit
13: Specified torque over
F
u
n
c
t
i
o
n
Built-in function
Command setting volume operator operation (LOCAL/REMOTE
switching)
Command setting volume is mounted
on the operation panel.
Dynamic brake
Dynamic brake by the power module Nch-ON
F
u
n
c
t
i
o
n
I
n
p
u
t
*
1
Multi-function input 7 points
Select 7 points from the following 13 points:
1: CW operation command
2: CCW operation command
3: Selection of speed command 1
4: Selection of speed command 2
5: Selection of speed command 3
6: Selection of speed command 4
7: Selection of acceleration and deceleration time 1
8: Selection of acceleration and deceleration time 2
9: Selection of torque limit value 1
10: Selection of torque limit value 2
11: Selection of torque limit value 3
12: Brake output forcibly ON command
13: Emergency stop/error reset input
Free-run stop/error reset
Stop free-run or reset the error occurred while detecting drivers.
Analog command
You can select either speed command or torque command from
the constant settings.
D
i
s
p
l
a
y
Status display LED
POWER and ALARM display
* It can be checked only when the operator is removed
Operator
7 segments LED x 5 digits
Monitor display: Switching display such as speed command,
load factor, and current value
Constant display: Constant value confirmation and constant input