Pn030
~
Pn037
Torque limit value 1
~
8
Pn038
Operator torque limit value
Set the motor output torque limit.
[Torque limit value 1
~
8 (Pn030
~
Pn037) and operator torque limit value (Pn038)]
The torque limit value settings corresponding to the torque limit value selection are as follows:
Pn039
Maximum value of the analog torque limit level
Set the maximum torque limit value of the external analog input and command setting volume.
* Select the external analog command and command setting volume command by Pn200.
Select the torque limit value 1
~
8 and operator torque limit value by using the Multi-function input: Selection of torque limit
value 1
~
3.
Torque limit value 2 (Pn031)
Torque limit value 3 (Pn032)
Torque limit value 4 (Pn033)
OFF
ON
ON
Torque limit value 5 (Pn034)
Torque limit value 6 (Pn035)
Torque limit value 7 (Pn036)
Torque limit value 8 (Pn037)
OFF
ON
ON
ON
ON
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
OFF
Selection of
torque limit 3
OFF
OFF
OFF
ON
OFF
Torque limit
OFF
Selection of
torque limit 1
Selection of
torque limit 2
External analog command
Command setting volume
Torque limit value 1 (Pn030)
Operator torque limit value (Pn038) *
* Select the external analog command, command setting volume, torque limit value 1 and operator torque limit value by