Control System
75
Service Manual – CS7000
Troubleshooting
Control Panel LEDs all stay lit - CAN Bus problems
If communication on the CAN bus fails, the operator may or may not notice anything. If they notice anything
it will likely be that the control panel powers up when the key is turned on but all of the LEDs remain lit
and there is no response to pushing any switch on the control panel.
Control panel appearance with CAN Bus failure
If this happens, start by checking to see if either the steering controller or drive controller is causing the
problem by unplugging their low current connectors one at a time. If normal operation is restored after
unplugging one of the controllers, that controller is corrupting the communication on the CAN Bus and
should be replaced.
Next inspect the CAN Bus wires for shorts to ground, shorts to power or short to one another.
• Turn the key off and unplug the control panel, the main machine controller, steering controller and the
drive controller connectors.
• At the main machine controller connector, check for the presence of voltage on each of the CAN Bus wires.
If there is voltage (example 12v or 36v), the wire is shorted to a voltage source. Find and correct the short
circuit.
• Using an ohmmeter, check for continuity between each of the CAN Bus wires and battery negative. If
continuity is found, there is a short to ground (battery negative). Find and correct the short circuit.
• Using an ohmmeter, check the continuity of all of the wires from the main machine controller connector
to each of the other connectors. If any wire does not have continuity there is an open. Find and correct the
open circuit.
If the wiring is not the problem, check to see if the main machine controller is capable of providing the
“bias” voltage on the circuit.
• Make sure the key is off and then plug in only the main machine controller.
• Turn the key on and then check the voltage on each of the CAN Bus wires at the Control Panel Connector.
If there is no voltage, the main machine controller is defective because it is not providing bias voltage.
If the voltage on the CAN Hi (YEL) wire is approximately 3.3v and the voltage on the CAN Low (GRN) wire
is approximately 1.8v, the main machine controller is providing the bias voltage. This indicates that the
control panel is the source of the problem and needs to be replaced.
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...