Service Manual – CS7000
DustGuard™ Spray System (optional)
The
DustGuard Pump
pumps water from a separate
reservoir in the upper hopper to
Nozzles
on the
front of the machine. The
Nozzles
direct a fine
stream of water onto the floor in front of the side
brooms to help reduce the dust generated by the
brooms.
The DustGuard™
Solenoid Valve
opens to allow
water flow from the
DustGuard Pump
to the
Nozzles
when the power to the
DustGuard Pump
switches
on. A removable
Strainer
is installed in the water
line upstream of the
DustGuard Pump
and
Solenoid
Valve
. Removable strainers are also located inside
of the
Nozzle
assemblies.
When installed, the DustGuard
™
spray system
will turn on automatically when the main broom/
sweep system is turned on.
Strainer
Solenoid
Valve
DustGuard
Pump (inside
Pump Guard)
DustGuard
Pump
Solenoid
Valve
Nozzles
Strainer
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...