Recovery System 299
Service Manual – CS7000
To Remove and Reinstall a Vacuum Motor
1.
Lift up the
Recovery Tank Cover
.
2.
Remove one of the
Hinge Tabs
, then twist and
remove the
Recovery Tank Cover
from the
Vacuum Fan Cover Assembly
. This will allow
access to the screw underneath the
Recovery
Tank Cover
that holds the
Vacuum Fan Cover
Assembly
to the recovery tank.
3. Remove the five
Screws
and
washers holding the
Vacuum Fan
Cover Assembly
to the recovery
tank.
4. Carefully lift the
Vacuum Fan
Cover Assembly
off of the recovery
tank, making sure the
Float Cages
pass up through the cutouts in the
tank.
5.
Disconnect the
Vacuum Motor
electrical connector.
6.
Loosen the
Hose Clamp
and
disconnect the
Foam Tube
Assembly
from the
Vacuum Motor
.
7. Carefully lift the
Vacuum Motor
out
of the recovery tank.
8. Reinstall the
Vacuum Motor
by
following the above steps in
reverse order.
Note:
Before you reinstall a
vacuum motor, check
the
Vacuum Fan Seal
Assembly
and the
Vacuum Duct Gaskets
for any wear or
damage and replace
if necessary.
Vacuum
Fan Cover
Assembly
Hinge
Tab
Recovery
Tank Cover
Screw (5)
Vacuum
Fan Cover
Assembly
Float
Cage (2)
Vacuum
Duct
Gasket (2)
Vacuum
Motor (2)
Vacuum
Fan Seal
Assembly
Foam Tube
Assembly (2)
Hose
Clamp (2)
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...