Solution System 340
Service Manual – CS7000
To Remove and Reinstall the Solution Solenoid Valve
Service Note:
You can remove and the reinstall the solution solenoid valve with the scrub deck
either in or out of the machine.
1. Empty and remove the recovery tank from the machine.
2. Remove the scrub deck from the machine (if desired). (Refer to the
Scrub System
section.)
3. Disconnect the
Electrical Connector
on the
Solution Solenoid Valve
from
the adjacent wiring harness. Note
that you may need to cut the wire tie
holding the
Solution Solenoid Valve
wires to the
Solution Manifold
.
4. Loosen the
Hose Clamp
holding the
Solution Solenoid Valve
to the
Solution
Manifold
.
5.
Remove the two
Hex Head Screws
holding the
Solution Solenoid Valve
to the deck assembly and remove
the
Solution Solenoid Valve
from the
machine.
6.
Reinstall the
Solution Solenoid Valve
following the above steps in reverse
order.
To Remove and Reinstall a Detergent Pump (EcoFlex™ Models Only)
1. Lift up the Operator seat and engage
the
Seat Prop Rod
.
2. Remove the detergent bottles.
3.
Remove the two
Screws
holding the
Cover Weldment
and remove the
Cover
Weldment
.
Hose
Clamp
Hex Head
Screw (2)
Solution
Solenoid
Valve
Electrical
Connector
Solution
Manifold
Seat
Prop
Rod
Screw (2)
Cover
Weldment
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...