Control System
53
Service Manual – CS7000
Fault Code Table (Main machine controller)
Fault # Description
Setting Conditions
Consequences
None
Power Distribution Fault
If the voltage of the 36v battery
pack falls too low, the LCD will
display this message. You need
to charge the 36v battery pack.
00
Auxiliary Contactor (K9) Winding
Circuit Overload
Short circuit or > 4 Amps
01
12 Volt Alternator is not charging
Battery voltage is less than 10
volts with the engine running
02
Not used
03
Not used
04
Excessive Engine Temperature*
Engine Temperature switch
closed with the engine running.
Shut down engine
05
Low Engine Oil Pressure*
Loss of engine run signal (Oil
pressure switch open) with the
key switch still on.
Shut down engine
06
Glow Plug Relay Overload
07
42 Volt Alternator is not charging
< 37 volts for > 30 Seconds.
08
Throttle 1 circuit overload
Current Overload
09
Throttle 2 circuit overload
Current Overload
Fault # Description
Setting Conditions
Consequences
10
Start Command circuit overload
> 18 Amps
11
Ignition On circuit overload
> 18 Amps
Fault # Description
Setting Conditions
Consequences
12
VACC1 circuit breaker tripped
Aux Contactor energized with
no voltage at J2-13 VACC1
13
VACC2 circuit breaker tripped
Aux Contactor energized with
no voltage at J3-26 VACC2
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...