Control System
66
Service Manual – CS7000
– 3 Vacuum Off Delay - Sets the timeout for the vacuum during the recovery power down sequence.
◦
RANGE: 12 - 20 seconds
◦
INCREMENT: 1 second
◦
DEFAULT: 12 seconds
– 4 Recovery Mode - Sets when the recovery system begins the power down sequence (only when the
Scrub System is being shut off). This is only affective when the system is operating when turned off.
◦
1
Normal
- starts immediately
◦
2 Neutral - waits for the machine to return to neutral
– 5 Detect RTF (Recovery Tank Full) The machine is equipped with a feature that will automatically
shut off the vacuum and scrub systems and display a recovery tank full icon on the control panel
display when the recovery tank becomes full. If problems are encountered with the vacuum shutoff
feature, such as the vacuum shutting off even when the recovery tank is not full, this feature can be
turned off.
◦
1 No - Do not detect recovery tank full
◦
2
Yes
- Detect recovery tank full
• 4 User Lockouts
– 1 Spd Control Adjust (Battery only) - Blocks the user from increasing the speed when scrubbing or
sweeping.
◦
Unlocked
◦
Locked
– 2 Scrub Mode Adjust - Blocks the user from changing scrub mode settings.
◦
1
Unlocked
◦
2 Detergent - Prevents the user from changing detergent settings.
◦
3 Detergent & Sol - Prevents the user from changing detergent and solution settings.
• 5 Extended Scrub System
– Start Up State
◦
Off – always disabled when the scrub system is activated.
◦
On – always enabled when the scrub system is activated.
◦
Last State
– returned to state when the scrub system was last on.
• 6 Low Voltage cutout - The batteries are monitored. Once the voltage drops below the cutout level,
various systems are shut down to prevent depleting the batteries. The batteries must be charged above a
reset level before normal operation is allowed. The LVC clearing will set the batteries to full. This setting
adjusts the cutout and reset voltages. The description is on a “per cell” basis. There are 18 cells.
– 1
1.75V, 2.15V
– 2 1.75V, 2.09V
– 3 1.83V, 2.09V
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...