Solution System 327
Service Manual – CS7000
EcoFlex™ Detergent Bottles and Pumps
The
EcoFlex™ Detergent Bottles
are located
underneath the Operator seat and supply
detergent to the two
EcoFlex™ Detergent
Pumps
. The two
EcoFlex™ Detergent Pumps
run simultaneously and pump detergent
through separate lines that merge into one
main detergent supply line. The detergent
supply line is plumbed into the solution
supply upstream of the solution solenoid
valve.
High-pressure Spray System Pump
The
High-pressure Pump
is driven by an
Electric Clutch
run by a
Pulley
off of the
engine. The
Electric Clutch
is engaged and
drives the
High-pressure Pump
when the
Operator presses the high-pressure wand
switch
on the control panel.
EcoFlex™
Detergent
Bottle (2)
EcoFlex™
Detergent
Pump (2)
High-
pressure
Pump
Electric
Clutch
Pulley
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...