Engine System - LPG LEV 193
Service Manual – CS7000
Checking LPG Primary Pressure
1. Turn off the propane tank valve with the engine
running and allow the engine to run out of fuel.
2. Turn key switch off.
3. Swing out the propane tank.
4. Remove the steel plate.
5. Remove the primary chamber test port plug
located on top of the vaporizer regulator and install
the test fitting.
6.
Install fitting from LPG pressure test kit into the
thread adapter.
7.
Using the LPG test gauge kit - Part # 56504450,
hook up the blue pressure gauge hose to the fitting.
8.
Open propane tank valve.
9.
Start engine. (Specification - 4.3 PSI, 32.7kPA)
10.
When finished, reinstall the test port plug using a
suitable pipe thread sealant. (E.G. Loctite 30534)
Remove Steel
Plate