Dust Control/DustGuard
™
Systems
89
Service Manual – CS7000
DustGuard™ Spray System
The
DustGuard Pump
is mounted on the
Upper Hopper
and
is protected by the
Pump Guard
. The
Strainer
screens the
incoming water upstream of the
DustGuard Pump
. The
Solenoid Valve
, downstream of the
DustGuard Pump
, opens
to allow water flow to the nozzles when the power to the
DustGuard Pump
is switched on.
The
Spray Nozzles
are mounted on the
front of the machine and spray an oval
pattern of water mist across the width of
each side broom.
Upper
Hopper
Pump
Guard
Strainer
Solenoid
Valve
DustGuard
Pump
Spray
Nozzles