Control System
54
Service Manual – CS7000
Fault # Description
Setting Conditions
Consequences
14
VACC3 circuit breaker tripped
Aux Contactor energized with
no voltage at J3-34 VACC3a
and J3-35 VACC3b
15
VACC6 circuit breaker tripped
Key on with no voltage at J2-34
VACC6a and J2-35 VACC6b
16
Scrub Deck Actuator (M11)
Overload
> 7 Amps for 4 seconds or short
circuit
Disables detergent,
solution and scrub motors.
17
Main Broom Actuator (M21)
Overload
> 6 Amps for 4 seconds or
short circuit
Disables sweep functions.
18
Side Broom Actuator (M13)
Overload
> 7 Amps for 4 seconds or short
circuit
Disables side brooms.
19
Side Broom Contactor (K8)
Winding Circuit Overload
> 4 Amps or short circuit
Disables side brooms.
20
Dust Control Contactor (K6)
Winding Circuit Overload
> 4 Amps or short circuit
Disables dust control.
21
Left Brush Contactor (K1)
Winding Circuit Overload
> 4 Amps or short circuit
Disables detergent,
solution and scrub motors.
22
Center Brush Contactor (K2)
Winding Circuit Overload
> 4 Amps or short circuit
Disables detergent,
solution and scrub motors.
23
Right Brush Contactor (K3)
Winding Circuit Overload
> 4 Amps or short circuit
Disables detergent,
solution and scrub motors.
24
Broom Contactor (K4) Winding
Circuit Overload
> 4 Amps or short circuit
Disables sweep functions.
25
Hydraulic Pump1 Contactor (K4)
Winding Circuit Overload
> 4 Amps or short circuit
26
Hydraulic Pump2 Contactor (K4)
Winding Circuit Overload
> 4 Amps or short circuit
27
Dust Filter Plugged
Closed switch
Warning message only
28
Dump Door Actuator (M26)
Overload
> 7 Amps for 4 seconds
Disables sweep functions
and hopper door.
29
Hopper Over Temperature
Closed hopper temperature
switch
Turns off the Dust Control
motor, the Main Broom
system, the Side Broom
system, and closes the
hopper dump door.
30
Shaker Motor (M14) Overload
> 20 Amps or short circuit
31
Solution Pump (M19) or
Extended Scrub Pump (M25)
Overload
> 24 amps or short circuit
32
High Pressure Washer Pump
Electromagnetic Clutch Overload
> 18 Amps or short circuit
33
Low Pressure Wash Pump (M23)
Overload
> 20 Amps or short circuit
34
Dust Guard Pump (M22)
Overload
> 20 Amps or short circuit
35
Solution Solenoid Valve (L1)
Winding Overload
> 4 Amps or short circuit
Disables detergent,
solution and scrub motors.
36
Chemical (Detergent) pump M17
overload
> 2.5 Amps or short circuit
Disables detergent.
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...