Engine System - LPG 177
Service Manual – CS7000
6. Using the LPG test gauge kit - Part # 56504450,
hook up the blue pressure gauge hose to fitting.
7. Open propane tank valve.
8.
Start engine. (Specification - 4.3 PSI, 32.7kPA)
9.
When finished, reinstall the test port plug using
a suitable pipe thread sealant. (E.G. Loctite
30534)
No crank - The starter does not engage
Possible causes:
• 36v battery pack drained (preventing main machine controller from powering up.)
• Engine Battery
• Starter
• Battery to starter cable
• Engine Ground
• No voltage to the starter solenoid
– Open circuit breaker CB9
– Auxiliary Relay
◦
Burned contacts or not energized
– Key Switch
– Main Machine Controller
– Woodward L Series Actuator (Not supplying ground for crank request relay)
– Crank request relay
• Wiring
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...