Engine System - Petrol (Gasoline) 202
Service Manual – Haram Captor II
Engine Starter and Carburetor Choke Control
To get the engine starter to engage, the key switch is held in the start position which supplies
36 volts to the main machine controller on the violet wire with the green stripe to connector J7
pin 19. This is the start input request. The main machine controller receives a 12 V supply on
connector J3 pin 23 from the engine starter battery. It uses this voltage supply to send 12 volts out
of connector J3 pin 10 to the crank request relay coil. The other side of the relay coil is grounded
through the Woodward L-series actuator. With power and ground across the relay winding the
relay energizes and fused battery power from terminal 30 is sent to the starter solenoid. An
electrically operated solenoid pulls the carburetor choke closed when the starter is engaged.
15A
12v BATTERY
STARTER
CRANK
REQUEST
RELAY
Main Machine Controller
Ground
Battery
Cranking
12v
WOODWARD
L-SERIES
ACTUATOR
36v BATTERY
36v
Aux. Relay Contact
12v
Key Switch
Start Position
Choke
Solenoid
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...