Scrub System 312
Service Manual – CS7000
To Remove and Reinstall a Scrub Motor Assembly
1. Remove the scrub deck from the machine.
2. Disconnect the electrical connector from the
Scrub Motor Assembly
.
3. Remove the
Scrub Brush
from the
Brush Plate
Assembly
.
4. Remove the
5/16-18 X 1.25 Socket Head Screw
from the gearbox shaft and carefully remove
the
Brush Plate Assembly
.
5. Remove the four
Hex Head Metric Screws
, then
lift the
Scrub Motor Assembly
and
Motor Spacer
off of the
Arm Weldment
(shown) or deck
weldment.
6. Reassemble the
Scrub Motor Assembly
following the above steps in reverse order.
Note:
Make sure the
Key
is installed
correctly before you reinstall the
Brush Plate Assembly
onto the
scrub motor shaft.
Scrub
Brush
5/16-18 X 1.25
Socket Head Screw
Scrub
Motor
Assembly
Electrical
Connector
Motor
Spacer
Brush Plate
Assembly
Key
Hex Head Metric
Screw (4)
Arm
Weldment
Summary of Contents for CS7000 Fuel Cell EcoFlex
Page 147: ...Electrical System 147 Service Manual CS7000 56509170 Rev L Sheet 1 of 9 ...
Page 148: ...Electrical System 148 Service Manual CS7000 56509170 Rev L Sheet 2 of 9 ...
Page 149: ...Electrical System 149 Service Manual CS7000 56509170 Rev L Sheet 3 of 9 ...
Page 150: ...Electrical System 150 Service Manual CS7000 56509170 Rev L Sheet 4 of 9 ...
Page 151: ...Service Manual CS7000 151 Electrical System 56509170 Rev L Sheet 5 of 9 ...
Page 155: ...Electrical System 155 Service Manual CS7000 56509170 Rev L Sheet 9 of 9 ...
Page 357: ...Steering System 357 Service Manual CS7000 Steering System Wiring Diagram 36 V From Key Switch ...