GZ550-1KT BLOWER
INSTALLATION INSTRUCTIONS
ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER
and must be connected and grounded in accor-
dance with local codes. In the absence of local codes, use the current CSA C22.1
CANADIAN
ELECTRICAL
CODE
in Canada or the
current ANSI/NFPA 70
NATIONAL
ELECTRICAL
CODE
in the United States.
A junction box, receptacle and cover plate are necessary to complete this installation. Because some fi replace models may not
come equipped with one, a junction box specifi c for this application (part # W010-0482) may be ordered from your Wolf Steel /
Napoleon
®
dealer.
If the fi replace was not previously equipped with a
blower:
route a grounded 2-wire, 60hz power cable to
the junction box. At this point, it must be strain relieved
and insulated.
ALL MODELS (40 SERIES EXEMPTED):
The three slots on the mounting bracket allow ease of adjustment when attach-
ing the blower. For a quiet running blower, do not allow the assembly to sit on
the fi rebox base.
Slide the vibration reducing pad
(A)
into the clip
(C)
and up against the threaded
stud
(B)
at the other end. The blower must be able to be positioned entirely onto
the pad.
Tilt the blower assembly onto its side. Slide it past the controls and into the clip
(C)
. Secure to the threaded stud using
the lock washer and wing nut provided. Ensure that the blower does not touch the fi replace base or the fi rebox.
Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the
securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the
fi rebox wall.
W415-0135 / B / 01.11.07
A
B
C
This kit includes:
QTY. DESCRIPTION
PART
#
1
Blower Assembly
GZ552
1
Blower Bracket
W080-0067
1
Wire Harness
W750-0050
1
Thermodisc
C
/
W
Bracket
W010-0367
1
Vibration Reducing Pad
W361-0037
2
Wing Nuts
W450-0009
2
Lock Washers
W735-0001
1
Variable Speed Switch
C
/
W
Knob
KB-35
Continue with ALL MODELS