56
Digitax HD M753 Control User Guide
Issue Number: 3
set according to the drive operating mode selected and saved in
memory.
6.4.9 Status information
This parameter controls access via the drive keypad as follows:
The keypad can adjust this parameter even when user security is set.
The parameter displays the software version of the drive.
Each bit in this parameter has the following functions:
Example
Pr
00.051
= 8 (1000
binary
) Th Brake Res trip is disabled
Pr
00.051
= 12 (1100
binary
) Th Brake Res and phase loss trip is disabled
Stop on non-important trips
If bit 0 is set to one the drive will attempt to stop before tripping if any of
the following trip conditions are detected: I/O Overload, An Input 1 Loss,
An Input 2 Loss or Keypad Mode.
Disable braking resistor overload detection
For details of braking resistor overload detection mode see Pr
10.030
.
Disable phase loss trip
Normally the drive will stop when the input phase loss condition is
detected. If this bit is set to 1 the drive will continue to run and will only
trip when the drive is brought to a stop by the user.
Disable braking resistor temperature monitoring
Size 3, 4 and 5 drives have an internal user install braking resistor with a
thermistor to detect overheating of the resistor. As default bit 3 of
Pr
00.051
is set to zero, and so if the braking resistor and its thermistor
is not installed the drive will produce a trip (Th Brake Res) because the
thermistor appears to be open-circuit. This trip can be disabled so that
the drive can run by setting bit 3 of Pr
00.051
to one. If the resistor is
installed then no trip is produced unless the thermistor fails, and so bit 3
of Pr
00.051
can be left at zero. This feature only applies to size 3, 4 and
5 drives. For example if Pr
00.051
= 8, then Th Brake Res trip will be
disabled.
Disable parameter freeze on trip
If this bit is 0 then the parameters listed below are frozen on trip until the
trip is cleared. If this bit is 1 then this feature is disabled.
When
Serial Address
(00.037),
Serial Mode
(00.035),
Serial Baud Rate
(00.036),
Minimum Comms Transmit Delay
(11.026) or
Silent Period
(11.027) are modified the changes do not have an immediate effect on
the serial communications system. The new values are used after the
next power-up or if
Reset Serial Communications
(00.052) is set to one.
Reset Serial Communications
(00.052) is automatically cleared to zero
after the communications system is updated.
00.049 {11.044}
User Security Status
RW
Txt
ND
PT
OL
Menu 0 (0), All Menus (1),
Read-only Menu 0 (2),
Read-only (3),
Status Only (4),
No Access (5)
Menu 0 (0)
RFC-A
RFC-S
Security
level
Description
0
(Menu 0)
All writable parameters are available to be edited but
only parameters in Menu 0 are visible.
1
(All Menus)
All writable parameters are visible and available to be
edited.
2
(Read-only
Menu 0)
All parameters are read-only. Access is limited to Menu 0
parameters only.
3
(Read-only)
All parameters are read-only however all menus and
parameters are visible.
4
(Status Only)
The keypad remains in status mode and no parameters
can be viewed or edited.
5
(No Access)
The keypad remains in status mode and no parameters
can be viewed or edited. Drive parameters cannot be
accessed via a comms / fieldbus interface in the drive or
any option module.
00.050 {11.029}
Software Version
RO
Num
ND
NC
PT
OL
0 to 99999999
RFC-A
RFC-S
00.051 {10.037}
Action On Trip Detection
RW
Bin
US
OL
0 to 31
0
RFC-A
RFC-S
Bit
Function
0
Stop on non-important trips
1
Disable braking resistor overload detection
2
Disable phase loss stop
3
Disable braking resistor temperature monitoring
4
Disable parameter freeze on trip
Open-loop mode
RFC-A and RFC-S modes
(01.001)
(01.001)
(01.002)
(01.002)
(01.003)
(01.003)
Frequency Slaving Demand
(03.001)
(00.010)
(03.003)
(03.004)
(00.012)
(00.012)
(00.013)
(00.013)
(04.017)
(04.017)
(00.011)
(00.011)
(05.002)
(05.002)
(05.003)
(05.003)
(05.005)
(05.005)
(07.001)
(07.001)
00.052 {11.020}
Reset Serial Communications
RW
Bit
ND
NC
OL
Off (0) or On (1)
Off (0)
RFC-A
RFC-S
00.053 {04.015}
Motor Thermal Time Constant
RW
Num
US
OL
1.0 to 3000.0 s
89.0 s
RFC-A
RFC-S