170
Digitax HD M753 Control User Guide
Issue Number: 3
12.6
Menu 5: Motor control
Figure 12-13 Menu 5 Open-loop logic diagram
+
05.010
05.011
Rated
Power Factor
Number Of
Motor Poles
05.002
Output
Voltage
05.003
Output
Power (kW)
Ö
3 x V x I
Volt
L1
L2
L3
05.005
DC Bus
Voltage
05.009
Rated
Voltage
05.007
05.008
Rated
Current
Rated
Speed
05.006
Rated
Frequency
05.017
Stator
Resistance
05.015
Low Frequency
Voltage Boost
05.013
Dynamic V To F
Select
Transient
Inductance
04.002
04.020
04.017
04.001
Current
Magnitude
Magnetising
Current
Torque
Producing
Current
Percentage
Load
Motormap
05.012
Autotune
05.024
05.014
Open-Loop
Control Mode
05.001
Output
Frequency
05.004
Motor
RPM
1
0
Slip
compensation
Enable
Slip
Compensation
05.027
05.018
05.019
Maximum Switching Frequency
High Stability Space Vector Modulation
Hertz
05.020
05.035
Quasi Square Enable
Auto Switching Frequency Change Disable
05.031
Voltage Controller Gain
mm.ppp
mm.ppp
K
ey
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings
05.024
Stator
Inductance
05.025
05.036
05.039
Auto-Switching Frequency Step Size
Maximum Inverter Temperature Ripple
05.042
Reverse Output Phase Sequence
05.037
Switching
Frequency
05.059
Maximum Deadtime
Compensation
05.037
Current At Maximum
Deadtime Compensation
05.061
Disable Deadtime Compensation
02.001
Post Ramp
Reference
+
03.001
Frequency Slaving
Demand
1
0
03.013
Enable
Frequency
Slaving
Summary of Contents for Digitax HD M753 EtherCAT