180
Digitax HD M753 Control User Guide
Issue Number: 3
06.068
Back Up Supply Mode Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
06.069
Under-Voltage System Contactor Close
Off (0) or On (1)
RO
Bit
ND
NC
PT
06.070
Under-Voltage System Contactor Closed
Off (0) or On (1)
Off (0)
RW
Bit
06.073
Braking IGBT Lower Threshold
0 to VM_DC_VOLTAGE_SET V
200 V drive: 390 V
400 V drive: 780 V
RW
Num
RA
US
06.074
Braking IGBT Upper Threshold
0 to VM_DC_VOLTAGE_SET V
200 V drive: 390 V
400 V drive: 780 V
RW
Num
RA
US
06.075
Low Voltage Braking IGBT Threshold
0 to VM_DC_VOLTAGE_SET V
0V
RW
Num
RA
US
06.076
Low Voltage Braking IGBT Threshold Select
Off (0) or On (1)
Off (0)
RW
Bit
06.084
Date And Time Offset
± 24.00 Hours
0.00 Hours
RW
Num
US
Parameter
Range(
)
Default(
)
Type
OL
RFC-A / S
OL
RFC-A
RFC-S
RW Read / Write
RO
Read only
Num Number parameter
Bit
Bit parameter
Txt
Text string
Bin
Binary parameter
FI
Filtered
ND No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US
User save
PS
Power-down save
DE
Destination
Summary of Contents for Digitax HD M753 EtherCAT