Digitax HD M753 Control User Guide
179
Issue Number: 3
Parameter
Range(
)
Default(
)
Type
OL
RFC-A / S
OL
RFC-A
RFC-S
06.001
Stop Mode
Coast (0), Ramp (1), Ramp d
c I (2), dc I (3), Timed dc I (4),
Disable (5)
Coast (0), Ramp (1),
No Ramp (2)
Ramp (1)
Ramp (1)
No Ramp
(2)
RW
Txt
US
06.002
Limit Switch Stop Mode
Stop (0) or Ramp (1)
Stop (0)
RW
Txt
US
06.003
Supply Loss Mode
Disable (0), Ramp Stop (1),
Ride Thru (2)
Disable (0),
Ramp Stop (1),
Ride Thru (2),
Limit Stop (3)
Disable (0)
RW
Txt
US
06.006
Injection Braking Level
0.0 to 150.0 %
100.0 %
RW
Num
RA
US
06.007
Injection Braking Time
0.0 to 100.0 s
1.0 s
RW
Num
US
06.008
Hold Zero Speed
Off (0) or On (1)
Off (0)
On (1)
RW
Bit
US
06.009
Catch A Spinning Motor
Disable (0), Enable (1), Fwd Only (2), Rev Only (3)
Disable (0)
Enable (1)
RW
Txt
US
06.010
Enable Conditions
000000000000 to 111111111111
RO
Bin
ND
NC
PT
06.011
Sequencer State Machine Inputs
000000 to 111111
RO
Bin
ND
NC
PT
06.012
Enable Stop Key
Off (0) or On (1)
Off (0)
RW
Bit
US
06.013
Enable Auxiliary Key
Disabled (0), Forward / Reverse (1), Run Reverse (2)
Disabled (0)
RW
Txt
US
06.015
Drive Enable
Off (0) or On (1)
On (1)
RW
Bit
US
06.016
Date
00-00-00 to 31-12-99
00-00-00
RW
Date
ND
NC
PT
06.017
Time
00:00:00 to 23:59:59
RW
Time
ND
NC
PT
06.018
Day Of Week
Sunday (0), Monday (1), Tuesday (2), Wednesday (3),
Thursday (4), Friday (5), Saturday (6)
RO
Txt
ND
NC
PT
06.019
Date/Time Selector
Set (0), Powered (1), Running (2), Acc Powered (3),
Local Keypad (4), Remote Keypad (5),
Slot 1 (6), Slot 2 (7), Slot 3 (8), Slot 4 (9)
Powered (1)
RW
Txt
US
06.020
Date Format
Std (0) or US (1)
Std (0)
RW
Txt
US
06.021
Time Between Filter Changes
0 to 30000 Hours
0 Hours
RW
Num
US
06.022
Filter Change Required / Change Done
Off (0) or On (1)
Off (0)
RW
Bit
ND
NC
06.023
Time Before Filter Change Due
0 to 30000 Hours
RO
Num
ND
NC
PT
PS
06.024
Reset Energy Meter
Off (0) or On (1)
Off (0)
RW
Bit
06.025
Energy Meter: MWh
-999.9 to 999.9 MWh
RO
Num
ND
NC
PT
PS
06.026
Energy Meter: kWh
±99.99 kWh
RO
Num
ND
NC
PT
PS
06.027
Energy Cost Per kWh
0.0 to 600.0
0.0
RW
Num
US
06.028
Running Cost
±32000
RO
Num
ND
NC
PT
06.029
Hardware Enable
Off (0) or On (1)
RO
Bit
ND
NC
PT
06.030
Run Forward
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.031
Jog
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.032
Run Reverse
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.033
Forward/Reverse
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.034
Run
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.035
Forward Limit Switch
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.036
Reverse Limit Switch
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.037
Jog Reverse
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.039
Not Stop
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.040
Enable Sequencer Latching
Off (0) or On (1)
Off (0)
RW
Bit
US
06.041
Drive Event Flags
00 to 11
00
RW
Bin
NC
06.042
Control Word
000000000000000 to 111111111111111
000000000000000
RW
Bin
NC
06.043
Control Word Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
06.044
Active Supply
Off (0) or On (1)
RO
Bit
ND
NC
PT
06.045
Cooling Fan control
0 to 11
10
RW
Num
US
06.047
Input Phase Loss Detection Mode
Full (0), Ripple Only (1), Disabled (2)
Full (0)
RW
Txt
US
06.048
Supply Loss Detection Level
0 to VM_SUPPLY_LOSS_LEVEL V
200 V drive: 205 V
400 V drive: 410 V
RW
Num
RA
US
06.051
Hold Supply Loss Active
Off (0) or On (1)
Off (0)
RW
Bit
NC
06.052
Motor Pre-heat Current Magnitude
0 to 100 %
0 %
RW
Num
US
06.058
Output Phase Loss Detection Time
0.5 s (0), 1.0 s (1), 2.0 s (2), 4.0 s (3)
0.5 s (0)
RW
Txt
US
06.059
Output Phase Loss Detection Enable
Disabled (0) or Enabled (1)
Disabled (0)
RW
Txt
US
06.060
Standby Mode Enable
Off (0) or On (1)
Off (0)
RW
Bit
US
06.061
Standby Mode Mask
0000000 to 1111111
0000000
RW
Bin
US
06.065
Standard Under Voltage Threshold
0 to VM_STD_UNDER_VOLTS V
200 V drive: 230 V
400 V drive: 330 V
RW
Num
RA
US
06.066
Low Under Voltage Threshold
24 to VM_LOW_UNDER_VOLTS V
200 V drive: 175 V
400 V drive: 330 V
RW
Num
RA
US
06.067
Low Under Voltage Threshold Select
Off (0) or On (1)
Off (0)
RW
Bit
US
Summary of Contents for Digitax HD M753 EtherCAT
Page 261: ......
Page 262: ...0478 0461 03...