Digitax HD M753 Control User Guide
193
Issue Number: 3
09.064
Scope Arm
Off (0) or On (1)
Off (0)
RW
Bit
NC
09.065
Scope Data Not Ready
Off (0) or On (1)
RO
Bit
ND
NC
PT
09.066
Scope Saving Data
Off (0) or On (1)
RO
Bit
ND
NC
PT
09.067
Scope Sample Time
1 to 200
4
RW
Num
US
09.068
Scope Trigger Delay
0 to 100 %
100 %
RW
Num
US
09.069
Scope Time Period
0.00 to 200000.00 ms
RO
Num
ND
NC
PT
09.070
Scope Auto-save Mode
Disabled (0), Overwrite (1), Keep (2)
Disabled (0)
RW
Txt
US
09.071
Scope Auto-save File Number
0 to 99
RO
Num
PS
09.072
Scope Auto-save Reset
Off (0) or On (1)
Off (0)
RW
Bit
09.073
Scope Auto-save Status
Disabled (0), Active (1), Stopped (2), Failed (3)
RO
Txt
PS
RW
Read / Write
RO
Read only
Num
Number parameter
Bit
Bit parameter
Txt
Text string
Bin
Binary parameter
FI
Filtered
ND
No default value
NC
Not copied
PT
Protected parameter
RA
Rating dependent
US
User save
PS
Power-down save
DE
Destination
IP
IP address
Mac
Mac address
Date
Date parameter
Time Time parameter
SMP Slot,menu,parameter
Chr
Character parameter
Ver
Version number
Parameter
Range(
)
Default(
)
Type
OL
RFC-A / S
OL
RFC-A
RFC-S