Figure 12-4 Menu 3 RFC-A, RFC-S logic diagram
* Automatic change over if the relevant ‘bit’ of
Position Feedback Initialized
(03.076) is 0.
02.001
Post-Ramp
Reference
+
+
0
1
0
1
03.023
01.011
Hard Speed
Reference
Select
Reference
On
Final Speed
Reference
03.022
Hard Speed
Reference
0
1
02.005
Disable Ramp
Output
VM_SPEED_FREQ_REF[MIN]
VM_SPEED_FREQ_REF[MAX]
03.001
03.027
P1 Speed
Feedback
03.127
7
P1 Interface
P2 Interface
P2 Speed
Feedback
16.027
25.027
15.027
26.027
Option Slot 1
P1 Speed Feedback
Option Slot 1
P2 Speed Feedback
Option Slot 2
P1 Speed Feedback
Option Slot 2
P2 Speed Feedback
0
1
2
3
03.024
RFC Feedback
Mode
0
1
3
2
4
5
d/dt
1
03.079
Sensorless
Mode Filter
03.080
d/dt
Sensorless
Position
03.026
Motor Control
Feedback Select
03.078
Sensorless Mode
Active