166
Digitax HD M753 Control User Guide
Issue Number: 3
12.5
Menu 4: Torque and current control
Figure 12-10 Menu 4 Open loop logic diagram
04.008
04.010
04.009
10.009
10.008
04.018
11.032
05.007
04.005
04.006
Motoring
Regenerating
Current limits
04.007
Symmetrical
Maximum
Heavy Duty
Rating
Rated
Current
Final
Current Limit
04.003
Final
Torque
Reference
Torque Offset
Torque
Reference
Torque
Offset
Select
+
Rated
Load Reached
Current Limit
Active
Current
Magnitude
Magnetising
Current
- Percentage
04.020
Load
- Current Feedback
04.021
Filter Disable
04.002
04.020
10.017
04.019
Motor
Protection
Accumulator
Motor Overload
Alarm
10.039
Braking Resistor
Thermal
Accumulator
04.004
Final Current
Reference
Torque to
current
conversion
05.006
Output
Frequency
05.001
Rated
Frequency
05.001
Motor map
2.01
Post Ramp
Reference
Output
Frequency
02.001
Torque Mode
Selector
04.011
04.013
04.014
P Gain
I Gain
Current loop
10.009
Current
Limit
Active
2.01
Pre Ramp
Reference
01.003
Menu 2 ramp
controller
+
+
_
+
+
04.001
04.017
04.002
Torque
Producing
Current
mm.ppp
mm.ppp
K
ey
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings
Overload
Detection
04.015
Motor Thermal Time Constant 1
04.016
Thermal Protection Mode
04.025
Low Speed Thermal Protection Mode
04.036
Motor Protection Accumulator Power Up Value
04.037
Motor Thermal Time Constant 2
04.038
Motor Thermal Time Constant 2 Scaling
04.039
Rated Iron Losses As Percentage Of Losses
Rated
Torque
04.026
Percentage
Torque
04.041
Summary of Contents for Digitax HD M753 EtherCAT
Page 261: ......
Page 262: ...0478 0461 03...