20
Digitax HD M753 Control User Guide
Issue Number: 3
4 Electrical installation
4.1
External 24 Vdc supply
An external 24 Vdc supply is required to power all the low voltage circuits within the drive.
The cable length between the 24 Vdc power supply and the drive should not exceed 10 m.
The 0V connection of the external 24 Vdc power supply should be connected to the same ground connection as the drive. Where this is not possible
the 0V connection of the 24 Vdc power supply should be floating.
The working voltage range of the drive 24 V power circuit is as follows:
Table 4-1 Working voltage range of the 24 Vdc supply
Table 4-2 24 Vdc typical input current and power requirements
During start up of the external 24 Vdc supply, allow for an additional 1 A for 300 ms.
The drive will power down and reset if the external 24 Vdc is removed.
WARNING
1
0V common
2
+24 Vdc
All frame sizes
Nominal operating voltage
24.0 Vdc
Minimum continuous operating voltage
20.4 V
Maximum continuous operating voltage
28.8 V
Minimum start up voltage
20.4 V
Maximum fuse rating
30 A
Model / Option / Feature
Frame size
Typical input current (mA)
@ 24 V
Typical input power
(W)
Digitax HD M75X drive module
1, 2
894
21.5
3
1039
25
SI-option module
Per module
450
11
High current brake output
All
1200
28.8
KI-Compact display
All
10
0.24
KI-Remote LCD keypad
All
73
1.75
NOTE
Summary of Contents for Digitax HD M753 EtherCAT
Page 261: ......
Page 262: ...0478 0461 03...