152
Digitax HD M753 Control User Guide
Issue Number: 3
12.3
Menu 2: Ramps
Figure 12-2 Menu 2 logic diagram
1
2
3
4
5
6
7
8
0 0 0
0 0 1
0 1 0
0 1 1
1 0 0
1 0 1
1 1 0
1 1 1
Acceleration Rate Select Bits
02.011
Acceleration Rate 1
02.012
Acceleration Rate 2
02.013
Acceleration Rate 3
02.014
Acceleration Rate 4
02.015
Acceleration Rate 5
02.016
Acceleration Rate 6
02.017
Acceleration Rate 7
02.018
Acceleration Rate 8
Acceleration rates 1 ~ 8
01.050
1
2
3
4
5
6
7
8
3
4
1
2
7
5
6
Preset Selected
I
ndicator
0
1
2
3
4
5
6
7
8
9
02.019
Jog Acceleration
Rate
0
1
01.013
Jog Select
01.003
Pre-Ramp Speed
Reference
02.003
Ramp Hold
02.004
Ramp Mode Select
N
t
N
t
Acceleration
Reverse
Accel. Rate
Forward
Accel. Rate
Ramp Control
02.010
Acceleration
Rate Selector
02.034
02.033
2.32
02.032
8
02.030
Acceleration
Rate Selected
02.008
02.009
Standard Ramp Voltage
Deceleration Fail Detection Disable
02.039
Ramp Rate Units
mm.ppp
mm.ppp
K
ey
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
X
X
X
X
The parameters are all shown in their default settings
02.007
Maximum Rate Of Change Of Acceleration
02.040
S Ramp Percentage
02.041
S Ramp Set Up Mode
02.042
Maximum Rate Of Change Of Acceleration 1
02.043
Maximum Rate Of Change Of Acceleration 2
02.044
Maximum Rate Of Change Of Acceleration 3
02.045
Maximum Rate Of Change Of Acceleration 4
Summary of Contents for Digitax HD M753 EtherCAT