Digitax HD M753 Control User Guide
209
Issue Number: 3
*The position controller is disabled and the error integrator is also reset under the following conditions:
1. If the drive is disabled (i.e. inhibited, ready or tripped)
2. If the position controller mode (Pr
13.010
) is changed. The position controller is disabled transiently to reset the error integrator.
3. The absolute mode parameter (Pr
13.011
) is changed. The position controller is disabled transiently to reset the error integrator.
4. One of the position sources is invalid.
5. The position feedback initialized parameter (Pr
03.048
) is zero.
mm.ppp
mm.ppp
K
ey
Read-write (RW)
parameter
Read-on
l
y (RO)
parameter
I
nput
termina
l
s
Output
termina
l
s
X
X
X
X
Orientation
13.014
13.015
Standard Motion
Orientation
acceptance
window
Standard Motion
Orientation
comp
l
ete
0
1
0
1
13.001 13.002 13.003
Standard Motion Error
Position
l
oop
enab
l
ed
*
0
1
2
3
4
5
6
0
1
1
06.008
Ho
l
d Zero
Speed
13.010
Standard Motion
Contro
ll
er
Mode
1
0
01.001
0
1
01.039
Reference
Se
l
ected
Speed
Feed-
Forwards
01.040
Speed Feed
-Forwards
Se
l
ect
01.003
Pre-Ramp
Reference
Menu 2
Ramp Contro
l
02.001
Post Ramp
Reference
+
13.009
13.012
03.022
Hard Speed
Reference
0
1
+
03.023
Hard Speed
Reference
Se
l
ect
03.001
Fina
l
Speed
Reference
Position
l
oop
disab
l
ed
Revo
l
utions Position Fine
Position
13.010
=
5 or
6
13.010
=
1 or 3
13.010
=
1 to
6
This
l
ogic diagram app
l
ies on
l
y when a
ll
parameters are at their defau
l
t settings
Standard Motion
Proportiona
l
G
ain
K
p
Standard Motion
Speed C
l
amp
Summary of Contents for Digitax HD M753 EtherCAT