228
Digitax HD M753 Control User Guide
Issue Number: 3
Card Error
SD Card data structure error
182
The
Card Error
trip indicates that an attempt has been made to access an SD Card but an error has been detected in the
data structure on the card. Resetting the trip will cause the drive to erase and create the correct folder structure. The cause
of the trip can be identified by the sub-trip.
Recommended actions:
•
Erase all the data blocks and re-attempt the process
•
Ensure the card is located correctly
•
Replace the SD Card
Card Full
SD Card full
184
The
Card Full
trip indicates that an attempt has been made to create a data block on an SD Card, but there is not enough
space left on the card.
Recommended actions:
•
Delete a data block or the entire SD Card to create space
•
Use a different SD Card
Card No Data
SD Card data not found
183
The
Card No Data
trip indicates that an attempt has been made to access non-existent file or block on an SD Card. No data
is transferred.
Recommended actions:
•
Ensure data block number is correct
Card Option
SD Card trip; option modules installed are different between source drive and destination drive
180
The
Card Option
trip indicates that parameter data or default difference data is being transferred from an SD Card to the
drive, but the option module categories are different between source and destination drives. This trip does not stop the data
transfer, but is a warning that the data for the option modules that are different will be set to the default values and not the
values from the card. This trip also applies if a compare is attempted between the data block and the drive.
Recommended actions:
•
Ensure the correct option modules
are installed.
•
Ensure the option modules are in the same option module slot as the parameter set stored.
•
Press the red reset button to acknowledge that the parameters for one or more of the option modules installed will be at
their default values
•
This trip can be suppressed by setting Pr
mm.000
to 9666 and resetting the drive.
Card Product
SD Card data blocks are not compatible with the drive derivative
175
If
Drive Derivative
(11.028) or
Product Type
(11.063) are different between the source and target drives then this trip is
initiated either at power-up or when the card is accessed. It will have one of the following sub-trip numbers:
Recommended actions:
•
Use a different SD Card
•
This trip can be suppressed by setting Pr
mm.000
to 9666 and resetting the drive
Trip
Diagnosis
Sub-trip
Reason
1
The required folder and file structure is not present
2
The <000> file is corrupted.
3
Two or more files in the <MCDF\> folder have the same file identification number.
Sub-trip
Reason
1
If
Drive Derivative
(11.028) is different between the source and target drives, this trip is initiated either at
power-up or when the SD Card is accessed. Data is still transferred, since this is a warning trip; the trip
can be suppressed by entering code 9666 in parameter xx.000, and resetting the drive (this applies the
warning suppression flag to the card).
2
If
Product Type
(11.063) is different between the source and target drives or if corruption is detected in
the parameter file, this trip is initiated either at power-up or when the SD Card is accessed. This trip can
be reset but no data are transferred in either direction between the drive and the card.
3
A Unidrive SP parameter value was found that has no equivalent parameter on the destination drive.
Data is still transferred, since this is a warning trip; the trip can be suppressed by entering code 9666 in
Pr
xx.000
, and resetting the drive (this applies the warning suppression flag to the card).