Summary
Preface
P. 6
Chapter 2
P. 17
Technical data
Chapter 5
P. 76
Reception, storage
and installation
Chapter 4
P. 54
General information
Chapter 3
P. 47
Application notes
Chapter 6
P. 115
Options
Chapter 7
P. 129
Preventive maintenance
Chapter 1
P. 15
Overview
and installation diagram
Answer Drives 1000
20
2
2.4 ALLOWABLE AMBIENT CONDITIONS
Table 2.4.1 Allowable ambient conditions
Operation:
Environmental temperature
Relative humidity
Contamination levels
Altitude
Vibrations
Environmental considerations
Storage:
Environmental temperature
Relative humidity
Altitude
Atmospheric pressure
Vibrations
Shock
Contamination levels
Environmental considerations
Operate in a stable place protected from weather according to IEC 721-3-3.
From 0 to 40 °C. (from 32 to 104 °F) – If the ambient temperature e 40°C (104 °F), reduce the rated output
temperature of 1% every °C (1.8°F). (max. 55°C – max. 131°F )
From 5 to 95% without condensation
(Coated boards) – Chemical gases: IEC 721-3-3, Class 3C2
Solid parts: IEC 721-3-3, Class 3S2
Up to 1000 m (3280 ft) above sea level. Above 1000 m (3280 ft) above sea level, the rated output current is reduced by
1% for every 100 m (328 ft) additional. Maximum height of 3000 m (9840 ft)
Max. 0.3 mm/0.012in (from 2 to 9 Hz), max. 1 m/s2 /3.28ft/s2 (from 9 to 200 Hz) sinusoidal (Class 3M1)
• Avoid exposure to corrosive gases - including hydrogen sulphide
• Avoid exposure to strong magnetic fields, nuclear radiation and high levels of RFI from communication transmitters
Store in a protective packaging and in a protected environment in accordance with IEC 721-3-1.
From -25°C to +70°C (From -13°F to +158°F)
Max 95% to 40 °C. – Max. 95% to 104 °F
Up to 3300 feet (or 1000 meters)
From 70 to 106 kPa
Max 1.5 mm / 0.06in. (from 2 to 9 Hz), max. max 5 m/s2 /16.4 ft/s2 (from 9 to 200 Hz) sinusoidal (class 1M3)
Max 100 m/s2 (330ft/s2), 11 ms (36fts) (class 1M3)
Coated boards – Chemical gases: IEC 721-3-3, class 1C2
Solid parts: IEC 721-3-3, class 1S3
• Avoid exposure to corrosive gases - including hydrogen sulphide.
• Avoid exposure to strong magnetic fields, nuclear radiation and high levels of RFI from communication transmitters
2.4 ALLOW
ABLE AMBIENT CONDITIONS
PREVIOUS VIEW
BACK 1.2
Summary of Contents for AD1A008FBBNH
Page 138: ......