6.4 STO (SAFE TORQUE OFF) FUNCTION
PRELIMINARY REMARKS
The STO function, certified with test report RP09DM4SN02 of 29/12/2009,
is available for AD1000 both with System and Basis control board
(excluding sizes AD1A0P3-022).
For a detailed description and instructions for use of the function to refer
to the document:
SAFETY FUNCTION USER MANUAL INSTRUCTION:
“STO” SAFE TORQUE OFF FOR DRIVE GT3000/5000 AND GT LARGE
The conditions of use of the STO safety function are described in the
above mentioned document, in accordance with IEC 60204-1 “Safety
of machinery - Electrical equipment of machines” (EN 60204-1:2006-06),
at paragraph 7 of IEC 61800-5-2: 2007 and in paragraph 11 of UNI EN
ISO 13849-1:2008.
The “CE Declaration of Conformity” supplied with the safety function
described above is valid only if all the conditions of use described in this
document are observed.
This document is part of the “accompanying documentation”
in compliance with the “Machinery Directive” 2006/42/EC and
“Low Voltage” Directive 2006/95/EC and will be considered as part of
the safety function itself.
6.5 IDENTIFICATION OF THE SAFETY FUNCTION
The components related to the “STO” function are factory-installed in the
drive and their presence is identified by the suffix in the drive identification
initials:
Number
Rev.
Date
MIM046
21
31/07/13
6.4 STO (SAFE TORQUE OFF) FUNCTION - 6.5
Safe Torque Off Function
N = Not Installed
T = STO board installed