2.7 GENERAL DATA
EN61800-2 (LOW VOLTAGE ELECTRIC DRIVES: GENERAL REQUIREMENTS)
EN61800-3 (ELECTRIC DRIVES: EMC REQUIREMENTS)
EN61800-5-1 (SAFETY REQUIREMENTS: ELECTRICAL, THERMAL AND ENERGY)
EN 50178 (ELECTRONIC EQUIPMENT IN POWER PLANTS)
Working temperature:
Storage temperature:
Three-phase voltage:
Relative humidity:
Altitude above sea level:
Degree of protection:
Cooling:
0-40°C (derating of 1%
for every °C, 55°C max)
from -25 to +70°C
F=380-480V ±10%
95% (non-condensing)
Frequency:
48-63Hz
1000m. (derating of 1% for every
100m, 3000m max)
Total power factor:
riferito alla fondamentale:
Efficiency:
0.93 to 0.96
>0,98 (with line reactor)
IP20 Sizes I-VIN
IP00 Sizes VII-VIII
with integrated fan
STANDARDS
ENVIRONMENTAL CONDITIONS (*)
CONNECTING TO THE POWER SUPPLY NETWORK
2.7 GENERAL DA
TA
0.98 max (50Hz- rated load)
(with output reactor)
(*) For detailed information see paragraph 2.4
BACK 1.2