- 101 -
NEW LEADER • NL5000G5 AGCO
www.New-Leader.com
(800) 363-1771
314520-AA-A
Page Rev. A
Header
Controller Operations
•
Enter starting spinner speed, spinner assembly fore/aft
scale position and desired swath width.
•
Turn on spinners and drive through the test course.
•
Collect and analyze spread pattern test results from
pans.
•
Make adjustments and repeat test as necessary to
achieve desired results.
•
Press
once an acceptable spread pattern has
been achieved.
•
Material profile is now successfully calibrated for low
and high rates. Press
to continue.
•
The next screen displays a summary of the test results
for each active bin. Press
to continue.
•
Enter name for new profile, and any desired notes.
Press
to continue.