NEW LEADER • NL5000G5 AGCO
Header
Alarms
GENERAL ALARMS
Alarm
Title
Description
WSM Spreader
Module
Local CAN Bus Error
Check the local CAN bus connection.
WSM Spreader
Module
Module Software Reset
The module software reset due to an
unhandled error.
WSM Spreader
Module
Local CAN Bus Warning
Check the local CAN bus connection.
WSM Spreader
Module
Local ISOBUS Error
Check the ISOBUS connections.
WSM Spreader
Module
Local ISOBUS Warning
Check the ISOBUS connections.
WSM Spreader
Module
CAN Power Voltage Low
The CAN power voltage is below 8.0 volts.
Check CAN bus power supply.
WSM Spreader
Module
High Power Voltage Low
The high power voltage is below 10.0 volts.
Check high power supply connections.
WSM Spreader
Module
Bin Not on Bus
Bin set as installed is not on bus. Check
wiring or edit the profile.
WSM Spreader
Module
Body Module Offline
The body module is no longer available.
Check power supply and communication
wiring.
WSM Spreader
Module
Module Indexing Failure
System has not indexed itself properly.
This can be caused by a missing index pin
in the cabling.