3.
Verify task control in Target Rate 1.
•
Rate will be driven by job setup in display. To verify
this, TC should show in place of target rate 1. If not,
verify job has been created correctly. Refer to display
manual.
4.
Verify total spread width and spinner speed:
•
Different products may require different spread widths
or spinner speeds. Always verify the material profile is
configured correctly before applying product.
•
Edit current profile or create a new one if necessary.
See “Material Profile Management” for details.
•
Enable Spinner Circuit. Using keypads, enter Spinner
Speed and Total Spread Width. If desired, enter Spinner
Offset (see
Boundary Spreading
section of this manual
for instructions).
5.
Verify gate opening:
•
Press
to set bin levels and change
gate opening.
Controller Operations