FAN FRAME ALARMS
Alarm
Description
Trigger
Fan Frame Not
Calibrated
“Fan Frame must be calibrated prior to
operation.” + [Sensor Name]
[Fan Frame Enable/Disable] is Enabled,
equipment profile is active and Fan Frame
position sensor has not been calibrated.
Fan Frame
Movement
“Fan Frame may move at this time. Keep
clear of Fan Frame.”
Upon startup, equipment profile is first
activated, [Fan Frame Enable/Disable] is
Enabled, and Swath Calibration has been
completed -or- upon user adjustment of the
[Target Fan Frame] setting.
Fan Frame
Movement During
Calibration
“Fan Frame will move during calibration.”
Fan Frame calibration routine has been
initiated, and system has been signaled to
move Fan Frame.
Home Position
Sensor Failure
During Application
“Home Position Sensor Error. Check Sensor
and Wiring.”
Conveyor is commanded on, Position Sensor
signal is lost during application.
Fan Frame Not
Responding
“Fan Frame Not Responding.” + [Sensor
Name]
Conveyor is commanded on, Fan Frame is
commanded to move, and no change in
position is detected from the position sensor
for five consecutive seconds or longer.
Fan Frame
Outside Expected
Operating Range
“Fan Frame position sensor outside
expected operating range. Check sensor and
wiring.” + [Sensor Name]
Upon user acknowledgement, dialog is
dismissed. System allows product application
at current Fan Frame position.
No Feedback from
Position Sensor
“No Feedback from Position Sensor.” +
[Sensor Name]
Conveyor is commanded on and system is not
receiving feedback from position sensor.