Troubleshooting 7-5
On-screen error message
Cause
Action
0252 Password checksum
bad -Password cleared
Password is cleared.
Reconfigure by using BIOS setup.
0260 System Timer error
System Timer is faulty.
0270 Real time clock error
RTC is faulty.
0271 Check date and time
setting
Date and time are incorrectly
set.
Reconfigure by using BIOS setup.
If the error cannot be solved after
this, replace the CPU/IO module.
02D0 System cache error –
Cache disabled
CPU cache is faulty.
02D1 System Memory
exceeds the CPU's
caching limit
CPU cache is faulty.
02F0 CPU ID
CPU is faulty
If replacing the CPU does not
help, replace the CPU/IO module.
0613 COM A configuration
change
COM A configuration is
faulty.
0614 COM A config, error –
device disable
Device constructing COM A
is faulty.
0615 COM B configuration
change
COM B configuration is
faulty.
0616 COM B config, error –
device disable
Device constructing COM A
is faulty.
If restarting does not help after
resetting the setting to default by
using BIOS setup, replace the
CPU/IO module.
0B28 Unsupported Processor
detected on Processor 1
Unsupported CPU is
mounted.
0B29 Unsupported Processor
detected on Processor 2
Unsupported CPU is
mounted.
Check the supported CPU and
replace it. If this does not help,
replace the CPU/IO module.
0B80 BMC Memory Test
Failed
RMC device is faulty.
0B81 BMC Firmware Code
Area CRC check failed
Replace the CPU/IO module.
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF check
Failed
RMC device is faulty.
Replace the CPU/IO module.
0B8B BMC progress check
timeout
BMC check is suspended.
Replace the CPU/IO module.
0B8C BMC command access
failed
BMC command access
failed.
Replace the CPU/IO module.
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC device is faulty.
Replace the CPU/IO module.
0B92 Internal Use Area of
BMC FRU corrupted
Data within SROM is faulty.
Replace the system backboard.
0B93 BMC SDR Repository
empty
SDR data is faulty.
If updating SDR does not help,
replace the CPU/IO module.
0B94 IPMB signal lines do not
respond
SMC is faulty.
Replace the CPU/IO module or a
system backboard after
determining where IPMB error
has occurred based on OS
information.
0B95 BMC FRU device failure
NVRAM within BMC is faulty.
Replace the CPU/IO module.
Summary of Contents for N8800-162F
Page 10: ...this page is intentionally left blank...
Page 43: ...General Description 2 7 Front View With front bezel attached With front bezel removed...
Page 46: ...2 10 General Description Rear View R320a E4 R320b M4...
Page 90: ...3 22 Linux Setup and Operation This page is intentionally left blank...
Page 107: ...System Configuration 4 17 Security Move the cursor onto Security to display the Security menu...
Page 124: ...4 34 System Configuration Exit Move the cursor onto Exit to display the Exit menu...
Page 136: ...4 46 System Configuration This page is intentionally left blank...
Page 212: ...6 16 Maintenance This page is intentionally left blank...
Page 236: ...7 24 Troubleshooting This page is intentionally left blank...
Page 267: ...System Upgrade 8 31 PCI 2 PCI 1 R320a E4 R320b M4 PCI 2 PCI 1 PCI 4 PCI 3 Riser Card...