8-6
Option
3.5-INCH HARD DISK DRIVE
The 3.5-inch hard disk drive bay in front of the server contains six slots in which hard disks with the
SCA2 interface are installed.
IMPORTANT:
You may conduct the installation, removal and replacement of hard disk drive by yourself.
However, if you are not familiar with procedures, NEC recommends that you request a
maintenance engineer of your service representative having the expert knowledge on the
server to do the installation and removal procedures.
Do not use any hard disk drives that are not authorized by NEC. Installing a third-party
hard disk drive may cause a failure of the server as well as the hard disk drive. Purchase the
hard disks of the same model in pair. Contact your service representative for hard disk
drives optimum for your server.
The OS starts from the hard disk that is mounted in Slot 1 of the primary module (whose
POWER LED is on).
When the PCI module operates in simplex mode (not in duplex mode), the mirroring
feature of the hard disk drive may be disabled at OS shutdown. OS will fail to start at
rebooting the server because the mirroring is disabled at the PCI module being offline (see
Chapter 7). Boot the server from the hard disk drive in PCI module that was in online state
at the OS shutdown.
A SCSI controller error having sraql160 as its source may sometimes be recorded in the
system event log. This error is likely to be issued when the hard disk drive processing
cannot keep up in time with requests of the OS, but the processing is carried on normally
thanks to the retry function. So, this does not affect the operation at all. In case such an
error is issued, check the detailed data indicated below, and if it is "f0030004" or
"f0030015," just ignore that log.
If, however, a SCSI controller error whose detailed data is "f0030004" or "f0030015" is
recorded repeatedly (ten times or more in a week time as a rough guide), a hard disk drive
failure is suspected. Contact the maintenance personnel in such a case.
Description:
The driver detected a controller error
on \Device\Scsi\sraql160x
[x is a numeral as 1 or 2 for example.]
In the case where the detailed data of
the above event properties is
represented in words, the error
represents no trouble if the value from
0034: is “f0030004" or “f0030015".
Summary of Contents for Express5800/340Hb-R N8800-047F
Page 1: ...N8800 047F 073F NEC Express5800 340Hb R User s Guide 1st Edition 3 2005 856 125126 901 A ...
Page 14: ...viii This page is intentionally left blank ...
Page 17: ...Precautions for Use 1 3 Label A Label B Label C Label D ...
Page 20: ...1 6 Precautions for Use Label A Label B Label C ...
Page 22: ...1 8 Precautions for Use Label A Label B Label C ...
Page 51: ...General Description 2 15 Chassis Board Layout Clock board Interface board Back panel ...
Page 76: ...2 40 General Description This page is intentionally left blank ...
Page 90: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume ...
Page 124: ...3 48 Windows Setup and Operation This page is intentionally left blank ...
Page 158: ...4 34 System Configuration This page is intentionally left blank ...
Page 171: ...Installing and Using Utilities 5 13 ...
Page 244: ...6 12 Maintenance This page is intentionally left blank ...
Page 278: ...7 34 Troubleshooting This page is intentionally left blank ...
Page 306: ...8 28 Option This page is intentionally left blank ...
Page 312: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...