5-22 Installing and Using Utilities
Change of SNMP Community
If the security setting of the SNMP Service of a system, where the NEC ESMPRO Agent is installed,
is changed from the default "public" to a community name, change the community settings of the
NEC ESMPRO Agent, too.
1.
Double-click the [NEC ESMPRO Agent] icon in [Control Panel].
2.
Select a desired community name from the [SNMP Community] list box in [SNMP
Setting] of the [General] sheet.
The community names to receive SNMP packets from are listed in the [SNMP
Community] list box.
3.
Click [OK] to terminate the operation.
Printer Information’s Available Time:
When you add a new printer, install its driver and make its settings, if you do not make settings for
the available time from Add Printer Wizard, the printer’s available time (From and To) in [Printers
and Faxes] are [00:00], on the other hand, Manager’s time are [9:00]. To display them properly,
make the settings of printer from [Printers and Faxes]. The procedures are as follows;
1.
Start [Printers and Faxes], and open the printer properties you want to make settings for.
(Select the [Printers and Faxes], right-click and select [Properties].)
2.
Select the [Advanced] tab.
3.
Enter values in the available time (From and To), and click [OK] in the [Advanced] and
[Properties] dialog boxes.
Now, you can see the correct information from Manager, too.
Disk Maintenance while NEC ESMPRO Agent is Running
The following works to disks (hard disk drive or magneto optical) are not allowed while NEC
ESMPRO Agent is running;
To format or delete a partition by Disk Administrator or by other means.
To request programmatically to remove media from removable disks such as MO, Zip and PD.
1.
Select the [Start] – [Settings] – [Control Panel]
2.
Open the [Service]
3.
Select a service named "ESMCommonService", and click the [Stop].
4.
Confirm that "ESMCommonService" stopped, and close the [Service].
5.
Do the disk-related works.
6.
Open the [Service] again, select "ESMCommonService" and click the [Start].
7.
Confirm that "ESMCommonService" is active and close the [Service] and [Control
Panel].
Summary of Contents for Express5800/340Hb-R N8800-047F
Page 1: ...N8800 047F 073F NEC Express5800 340Hb R User s Guide 1st Edition 3 2005 856 125126 901 A ...
Page 14: ...viii This page is intentionally left blank ...
Page 17: ...Precautions for Use 1 3 Label A Label B Label C Label D ...
Page 20: ...1 6 Precautions for Use Label A Label B Label C ...
Page 22: ...1 8 Precautions for Use Label A Label B Label C ...
Page 51: ...General Description 2 15 Chassis Board Layout Clock board Interface board Back panel ...
Page 76: ...2 40 General Description This page is intentionally left blank ...
Page 90: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume ...
Page 124: ...3 48 Windows Setup and Operation This page is intentionally left blank ...
Page 158: ...4 34 System Configuration This page is intentionally left blank ...
Page 171: ...Installing and Using Utilities 5 13 ...
Page 244: ...6 12 Maintenance This page is intentionally left blank ...
Page 278: ...7 34 Troubleshooting This page is intentionally left blank ...
Page 306: ...8 28 Option This page is intentionally left blank ...
Page 312: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...