3-42 Windows Setup and Operation
IMPORTANT:
If BrightStor ARCserve 2000 or Backup Exec is installed, the tape
will not be recognized due to the failover of the PCI module. Thus be sure to stop the
services before starting the PCI module.
1.
Start [Services] from [Administrative Tools] of [Control Panel].
2.
Select a service of backup software.
3.
Choose “Stop” from the “Action” menu.
4.
Repeat 2 and 3 for all services of the backup software.
The PCI modules’ status LEDs changes as shown below:
[Indications of the status LEDs]
Immediately after the PCI module startup until the completion of diagnosis
LED Secondary
Primary
1
BMC status LED
Green
Green
2
PCI module status LED1
Red
-
3
PCI module status LED2
Green
Amber
4
DISK ACCESS LED
-
Amber
DISK LED
Green
Amber
When duplication of disks is started after the completion of PCI module diagnosis
* The status of LEDs differ depending on the method of disk duplication.
Secondary
LED
Non-RDR
model
RDR
model
Primary
1
BMC status LED
Green
Green
Green
2
PCI module status LED1
-
-
-
3
PCI module status LED2
Amber
Green
Amber
4 DISK
ACCESS
LED
Amber
Green
Amber
DISK LED
Amber
Green
Amber
After the completion of disk duplication and when the PCI modules are duplicated
LED Secondary
Primary
1
BMC status LED
Green
Green
2
PCI module status LED1
-
-
3
PCI module status LED2
Green
Green
4
DISK ACCESS LED
Green or off
Green or off
DISK LED
Green
Green
Summary of Contents for Express5800/340Hb-R N8800-047F
Page 1: ...N8800 047F 073F NEC Express5800 340Hb R User s Guide 1st Edition 3 2005 856 125126 901 A ...
Page 14: ...viii This page is intentionally left blank ...
Page 17: ...Precautions for Use 1 3 Label A Label B Label C Label D ...
Page 20: ...1 6 Precautions for Use Label A Label B Label C ...
Page 22: ...1 8 Precautions for Use Label A Label B Label C ...
Page 51: ...General Description 2 15 Chassis Board Layout Clock board Interface board Back panel ...
Page 76: ...2 40 General Description This page is intentionally left blank ...
Page 90: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume ...
Page 124: ...3 48 Windows Setup and Operation This page is intentionally left blank ...
Page 158: ...4 34 System Configuration This page is intentionally left blank ...
Page 171: ...Installing and Using Utilities 5 13 ...
Page 244: ...6 12 Maintenance This page is intentionally left blank ...
Page 278: ...7 34 Troubleshooting This page is intentionally left blank ...
Page 306: ...8 28 Option This page is intentionally left blank ...
Page 312: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...