5-10 Installing and Using Utilities
Detection of Server Fault
NEC ESMPRO Manager and NEC ESMPRO Agent detect errors causing faults to occur at an early
stage and notify Administrators of fault information real-time.
Early detection of error
If a fault occurs, NEC ESMPRO Agent detects the fault and reports the occurrence of the
fault to NEC ESMPRO Manager (alert report). NEC ESMPRO Manager displays the
received alert in the alert viewer and also changes the status colors of the server and server
component in which the fault occurs. This allows you to identify the fault at a glance.
Further, checking the content of the fault and the countermeasures, you can take
appropriate action for the fault as soon as possible.
Types of reported faults
The table below lists the typical faults reported by NEC ESMPRO Agent.
Component Reported
information
CPU
•
CPU load is over the threshold
•
CPU degrading, etc.
Memory
ECC 1-bit error detection, etc.
Power supply
•
Voltage lowering
•
Power failure, etc.
Temperature Temperature
increase in cabinet, etc.
Fan
Fan failure (decrease in the number of revolutions), etc.
Storage
File system usage rate, etc.
LAN
•
Line fault threshold over
•
Send retry or send abort threshold over, etc.
Prevention of Server Fault
NEC ESMPRO Agent includes the preventive maintenance function forecasting the occurrence of a
fault as countermeasures for preventing faults from occurring.
NEC ESMPRO Manager and NEC ESMPRO Agent can set the threshold for the CPU usage rate
and the empty capacity in a file system, etc. in the server. If the value of a source exceeds the
threshold, NEC ESMPRO Agent reports the alert to NEC ESMPRO Manager.
The preventive maintenance function can be set for a variety of monitoring items including the CPU
usage rate.
Summary of Contents for Express5800/340Hb-R N8800-047F
Page 1: ...N8800 047F 073F NEC Express5800 340Hb R User s Guide 1st Edition 3 2005 856 125126 901 A ...
Page 14: ...viii This page is intentionally left blank ...
Page 17: ...Precautions for Use 1 3 Label A Label B Label C Label D ...
Page 20: ...1 6 Precautions for Use Label A Label B Label C ...
Page 22: ...1 8 Precautions for Use Label A Label B Label C ...
Page 51: ...General Description 2 15 Chassis Board Layout Clock board Interface board Back panel ...
Page 76: ...2 40 General Description This page is intentionally left blank ...
Page 90: ...3 14 Windows Setup and Operation 7 Configure the mirror of the extended volume ...
Page 124: ...3 48 Windows Setup and Operation This page is intentionally left blank ...
Page 158: ...4 34 System Configuration This page is intentionally left blank ...
Page 171: ...Installing and Using Utilities 5 13 ...
Page 244: ...6 12 Maintenance This page is intentionally left blank ...
Page 278: ...7 34 Troubleshooting This page is intentionally left blank ...
Page 306: ...8 28 Option This page is intentionally left blank ...
Page 312: ...B 4 IRQ and I O Port Address This page is intentionally left blank ...