Chapter 13 – Specific AT Commands
Multi-Tech Systems, Inc. CDMA Wireless AT Commands (PN S000294J)
87
Minute Alert +WMBP
Description:
This command is used to set the minute alert while in a voice conversation.
Values:
<mode>
0
Disable alert
1
Enable alert
<interval>
1 – 30
Time in minutes
Syntax:
Command syntax:
AT+WMBP=<mode>,<interval>
Command
Possible Responses
AT+WMBP=0
Note: Turn off the alert
OK
AT+WMBP=1,4
Note: Turn on the alert and set 4 minutes apart
OK
AT+WMBP?
Note: Request current setting
+WMBP: 1,4
AT+WMBP=?
Note: Display valid parameter ranges.
+WMBP: (0-1),(1-30)
Configure LED Indicator +CLED
Description:
This command is used to configure GPIO 41 and GPIO 54 for general purpose use. The default use of these
two GPIO’s is to drive LED indicators on the Developer Kit board. This command allows a user application to
disable this default behavior. When disabled, the user application has full control over the state of these
GPIO’s. The modem operating software will be prevented from change them for operational status
indications.
The byte value specified with the +CLED command is a bitmap where bit 0 configures LED1/GPIO 41 and
bit 1 configures LED2/GPIO 54. Bit positions 2 through 7 are ignored.
The state of the +CLED specified control bits is not persistent. Both bit positions are always set active (1)
during boot resulting in LED status indicator operation. The +CLED command must be used by the user
application after each boot if GPIO 41 or GPIO 54 are used for other purposes.
Values:
<bitmap value>
bit 0
0 = GPIO 41 selected; 1 = LED1 selected.
bit 1
0 = GPIO 54 selected; 1 = LED2 selected.
bit 2 – bit7
Reserved
Syntax:
Command syntax:
AT+CLED=<bitmap value>
Command
Possible Responses
AT+CLED?
Note: Display current settings.
CLED: 3
OK
Note: Both GPIO’s are used for modem operational status
indicators.
AT+CLED=?
Note: Display valid parameter range.
CLED: (0-3)
OK
AT+CLED=1
Note: Set bit 1 to inactive and bit 0 to active.
AT+WIOW=54,0
Note: Set GPIO state.
AT+WIOR=41
Note: Read state of LED1 indicator.
OK
Note: GPIO 54 available, LED1 used for modem status.
OK
Note: Set GPIO 54 to 0.
+WIOR: 1
OK
Note: Read current state of LED1 indicator
AT+CLED=2
Note: Set bit 1 to active and bit 0 to inactive.
AT+WIOW=41,1
Note: Set GPIO state.
AT+WIOW=54,1
Note: Set LED2 state.
OK
Note: LED2 used for modem status, GPIO 41 available.
OK
Note: Set GPIO 41 to 1.
OK
Note: LED2 indicator set to “on”. LED on/off state may
change due to modem status indication.