MRU GmbH
SWG 100 User Manual
Page
90
of
141
Position 1: Acid-gas filter (#56795)
Required materials
2x Acid gas filter (#56795), contained in the service- set.
Required tools:
Needle-nose pliers.
Exchange interval:
Exchange necessary, if filter turns from purple to white.
Mounting direction: Irrelevant
Steps:
1.
Remove exhausted acid gas filter from
the clips.
2.
Pull the Viton tubes from the exhausted
acid gas filter. If it is necessary, use
needle- nose pliers.
3.
Plug the Viton tubes on the new acid
gas filters. Be sure, that the tubing is
correct. (The single tubes are signed with
+
-
sketch on the right side.)
Steps:
Pull the Viton-tubes from the filter unit. If it is necessary, pliers can be used to solve
the tubes from the filter unit.
Remove the exhausted filter unit from the clip.
Plug the Viton tubes on the filter unit. Push the filter unit on the clip.
- Socket
+ Socket
Remove the
exhausted filter
unit.
Install a new filter
unit.
Summary of Contents for SWG 100 biogas
Page 1: ...MRU GmbH SWG 100 User Manual Page 1 of 141...
Page 2: ...MRU GmbH SWG 100 User Manual Page 2 of 141...
Page 13: ...MRU GmbH SWG 100 User Manual Page 13 of 141 Picture above Sample gas flow diagram...
Page 81: ...MRU GmbH SWG 100 User Manual Page 81 of 141 Device info Path EXTRAS DEVICE INFO Structure...
Page 86: ......
Page 92: ......
Page 133: ...MRU GmbH SWG 100 User Manual Page 133 of 141 13 15 Option NDIR bench for 0 3 000ppm CO2 0 CH4...
Page 140: ...MRU GmbH SWG 100 User Manual Page 140 of 141 14 Declaration of conformity...
Page 141: ...MRU GmbH SWG 100 User Manual Page 141 of 141 V01 02 EN...