![motortronics VMX-Synergy Plus User Manual Download Page 8](http://html1.mh-extra.com/html/motortronics/vmx-synergy-plus/vmx-synergy-plus_user-manual_1839367008.webp)
Installation
8
2.4 Enclosure Internal Clearances
2.5 Altitude De-rate
Altitude above sea level 1000m (
3281ft
). Above 1000m de rate by 1% of VMX-Synergy Plus
TM
Ie
per 100m (328ft) to a maximum altitude of 2000m (
6562ft
).
2.6 Temperature De-rate
VMX-SGY-I-17 to VMX-SGY-I-500
-20°C
[-4°F
] to 50°C [
122°F
]; above 50°C derate linearly by 4% of VMX-Synergy Plus
TM
Ie per °C to
a maximum of 60°C (
140°F
)
Model
A
B
C
mm
inch
mm
inch
mm
inch
VMX-SGY-I-17 to VMX-SGY-I-100
25
0.98
75
2.95
25
0.98
VMX-SGY-I-132 to VMX-SGY-I-195
40
1.57
100
3.93
25
0.98
VMX-SGY-I-242 to VMX-SGY-I-500
60
2.36
125
4.92
25
0,98
A
A
B
B
C